Thyroid Tt3 Diagnosis Chemiluminescence Immunoassay Kit 

Payment Terms: T/T,L/C,WU,Paypal 
Place of Origin: Jiangsu, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: NRM-411
Production Capacity: 1,000,000.00/Month
Delivery Date: TWO WEEKS AFTER PAYMENT
Methodology: Chemiluminescence
Specimen: serum
Type: Manufacturer
Means of Transport: Ocean,Land,Air
Packing: IN CARTON
Brand Name: NORMAN
Service: International after-sales
Manufacturer: Independent R & D
Test time: 18 min

Total Triiodothyronine (TT3) Kit (Chemiluminescence Immunoassay) is intended for in vitro quantitative determination of total triiodothyronine (TT3)

Thyroid Total Triiodothyronine (TT3) Chemiluminescence Immunoassay Reagent


Methodology                                                                                                         

Chemiluminescence Immunoassay


Product Show                                                                                                       Thyroid Total Triiodothyronine (TT3) Chemiluminescence Immunoassay Reagent                                                                              


TT3                                                                                                                          

Total Triiodothyronine (TT3) Kit (Chemiluminescence Immunoassay) is intended for in vitro quantitative determination of total triiodothyronine (TT3) content in human serum, based on NRM411 system.
Triiodothyronine (T3) is a hormone synthesized and secreted by thyroid or produced from its prohormone thyroxine (T4) outside thyroid. Its secretion is regulated by a negative feedback mechanism involving thyroid, pituitary and hypothalamus. In healthy populations, the concentration of T3 is 1/50 of that of T4. 99.7% of the T3 hormone reversibly binds to carrier proteins such as thyroxine-binding globulin (TBG), few albumins and prealbumins, and the rest T3 hormone remains in a free state. T3 is the true hormone. Its effects on target tissues are roughly four times more potent than  those of T4.


Clinical Significance                                                                                              

Thyroid dysfunction may cause excessive or insufficient secretion of T3. Besides, disorders of pituitary and hypothalamus will affect the secretion of T3 as thyroid function is directly affected by thyroid-stimulating hormone (TSH). The change of T3 concentration is more sensitive than that of T4 in some thyroid diseases. For example, the test of T3 concentration in blood is more helpful for the diagnosis of hyperthyroidism than that of T4. The level of T3 can also be a good measure of the storage of thyroid hormone in the body under the condition of strong stimulation to thyroid.


Test Principle                                                                                                           The assay is a competitive immunoassay for quantitative determination of TT3 concentration based on chemiluminescence immunoassay technology. The Magnetic Microbeads Reagent contains protecting reagents and magnetic microbeads that are coated with biotin labeled T3 antibody. The Antibody Reagent contains the protecting reagents and acridinium ester labeled BSA-T3 conjugate. Auxiliary Reagent contains dissociating agent and protecting reagents. Sample, calibrator or control is mixed with Magnetic Microbeads Reagent, Antibody Reagent and Auxiliary Reagent to form a sandwich complex. After incubation and automatic magnetic separation conducted by the instrument, trigger solutions are added to generate chemiluminescent reaction and the relative light units (RLUs) are measured by a photomultiplier. A proportional relationship presents between the concentration of TT3 in the sample and the RLUs detected by the NRM411 system.


Packages                                                                                                                

100 Tests/Box, 200 Tests/Box.


Storage and Stability                                                                                            

Sealed: Stable until the expiry date when stored at 2-8ºC.
Opened: Stable for 4 weeks for reagents. Stable for 1 week after dissolved/opened for solid control material/liquid control material. To ensure the kit's best performance, it is recommended to place opened kits in the refrigerator if it's not going to be used on board during the next 12 hours.
Do not use it beyond the expiration date.


Calibration and Traceability                                                                                

Calibration
Each batch of kits contains specific calibration information, stored in the Calibration Card.
Traceability
The TT3 assay is traceable to a NIFDC standard reference material (lot No. 150550-201203).


bigPhoto
 Ms. Ying Qin
Department Manager
Tel: 86-25-58602219
Mobile: 138 1471 7578
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Nanjing Norman Biological Technology Co., Ltd [China (Mainland)]


Business Type:Manufacturer
City: Nanjing
Province/State: Jiangsu
Country/Region: China (Mainland)

You May Like: