QR Code QR Code
Post Offer Free
Nanjing Norman Biological Technology Co., Ltd
Nanjing Norman Biological Technology Co., Ltd  

Gold Index: 24623

You are here: home  > Chemiluminescence Reagents  > Chemiluminescence immunoasssay Thyriod kits  > Thyroid FT3 Chemiluminescence Immunoassay Kit

Thyroid FT3 Chemiluminescence Immunoassay Kit 

Payment Terms: T/T,L/C,WU,Paypal 
Place of Origin: Jiangsu, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: NRM-411
Production Capacity: 1,000,000.00/Month
Delivery Date: TWO WEEKS AFTER PAYMENT
Methodology: Chemiluminescence
Specimen: serum
Type: Manufacturer
Means of Transport: Ocean,Land,Air
Packing: IN CARTON
Brand Name: NORMAN
Service: International after-sales
Manufacturer: Independent R & D
Test time: 18 min

The assay is a competitive immunoassay for quantitative determination of FT3 concentration based on chemiluminescence immunoassay technology.

Laboratory and Diagnostic Tests Lab FT3 Chemiluminescence Blood Tests

Methodology                                                                                                        

Chemiluminescence Immunoassay


Product Show                                                                                                                                                                                                                                                                                             
Thryoid Free Triiodothyronine (FT3) Chemiluminescence Immunoassay Reagent

FT3                                                                                                                           

Free Triiodothyronine (FT3) Kit (Chemiluminescence Immunoassay) is intended for in vitro quantitative determination of free triiodothyronine (FT3) content in human serum, based on NRM411 system.
Triiodothyronine is a hormone synthesized and secreted by thyroid or produced from its prohormone thyroxine (T4) outside thyroid. Roughly 80% of the circulating T3 is later formed in peripheral tissues by removal of the iodine atom from T4. In blood circulation, 99.7% of the T3 hormone reversibly binds to carrier proteins such as thyroxine-binding globulin (TBG), few albumins and prealbumins, and the rest T3 hormone remains in a free state. FT3 is the active form of hormone while the carrier protein bound T3 is not, thus the FT3 assay is meaningful to indicate thyroid function.


Clinical Significance                                                                                              

Thyroid dysfunction may cause excessive secretion of T3 and T4, and the level of FT3 in the body is related to the secretion and metabolism of T3. In patients with hypothyroidism and hyperthyroidism, the level of FT3 in the body changes along with level of total triiodothyronine. Therefore, the determination of FT3 is an important index for routine clinical evaluation of thyroid function. The results can be used as the basis for the diagnosis of different thyroid diseases such as different types of hyperthyroidism and T3 thyrotoxicosis.


Test Principle                                                                                                         

The assay is a competitive immunoassay for quantitative determination of FT3 concentration based on chemiluminescence immunoassay technology. The Magnetic Microbeads Reagent contains protecting reagents and magnetic microbeads that are coated with biotin labeled anti-T3 antibody. The Antibody Reagent contains the protecting reagents and acridinium ester labeled BSA-T3 conjugate. Auxiliary Reagent contains protecting reagents. Sample, calibrator or control is mixed with Magnetic Microbeads Reagent, Antibody Reagent and Auxiliary Reagent to form a sandwich complex. After incubation and automatic magnetic separation conducted by the instrument, trigger solutions are added to generate chemiluminescent reaction and the relative light units (RLUs) are measured by a photomultiplier. A proportional relationship presents between the concentration of FT3 in the sample and the RLUs detected by the NRM411 system.


Packages                                                                                                                 

100 Tests/Box, 200 Tests/Box.


Storage and Stability                                                                                            

Sealed: Stable until the expiry date when stored at 2-8ºC.
Opened: Stable for 4 weeks for reagents. Stable for 1 week after dissolved/opened for solid control material/liquid control material. To ensure the kit's best performance, it is recommended to place opened kits in the refrigerator if it's not going to be used on board during the next 12 hours.
Do not use it beyond the expiration date.


Calibration and Traceability                                                                                  Calibration
Each batch of kits contains specific calibration information, stored in the Calibration Card.
Traceability
The FT3 assay is traceable to a NIFDC standard reference material (lot No. 150550-201203).


                                                                                 


bigPhoto
 Ms. Ying Qin
Department Manager
Tel: 86-25-58602219
Mobile: 138 1471 7578
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Nanjing Norman Biological Technology Co., Ltd [China (Mainland)]


Business Type:Manufacturer
City: Nanjing
Province/State: Jiangsu
Country/Region: China (Mainland)

You May Like: