QR Code QR Code
Post Offer Free
Nanjing Norman Biological Technology Co., Ltd
Nanjing Norman Biological Technology Co., Ltd  

Gold Index: 24628

You are here: home  > Automated Chemiluminescence Immunoassay System (CLIA)  > automated chemiluminescence immunoassay analyzer NRM411-S7  > Seven Minute Cardiovascular Chemiluminescence Immunoassay Analyzer

Seven Minute Cardiovascular Chemiluminescence Immunoassay Analyzer 

Payment Terms: T/T,L/C,WU,Paypal 
Place of Origin: Jiangsu, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: NRM-411-S7
Production Capacity: 100 pieces/Month
Delivery Date: 1 month
Quality System Certificate: ISO13485
Application: Diagnosis & Theropy
Weight: 105.0kg
Temperature: 36.5 ± 0.5 Celsius
Sample Capacity: 12
Means of Transport: Ocean,Land,Air
Packing: Wooden box
Brand Name: NORMAN
Certificate: CE
Size: 710mm*710mm*740mm
Power: 220 ± 22AC
Testing Speed: 60 tests/hour
Reagent Capacity: 6

Direct chemiluminescence immunoassay provides accurate result and the linear
corrlation coefficient with Europe-America products ≥ 0.99

World's Fastest Seven Minutes Cardiovascular Chemiluminescence Immunoassay Analyzer


Automated Small-Sized Chemiluminescence Analyzer                                 

The Automated Chemiluminescence Analyzer NRM-411-S7 and corresponding reagent kits are used in the clinical and medical laboratory or hospital to conduct in vitro diagnostic luminescent reaction experiments.
The device used acridinium aster as a substrate for chemiluminescent reaction. NRM-411-S7 is able to diagnose thorough cardiovascular indicators, including H-FABP, NT-proBNP, D-Dimer, hs-cTnI, CK-MB, and Myoglobin, and bacteria markers, PCT. The device supports serum, plasma and whole blood samples, and the first diagnosis will be completed in 7 minutes, which is the one of the fastest chemiluminescence analyzer worldwide. Self-developed antigens and self-manufactured antibodies that ensures minimized intra and inter batch difference. The coefficient of variance of NORMAN-411-S7 is less than 5%, and testing result relevance with main stream Europe-America products is larger than 99%, both of which reveal the high accuracy and high precision of our product.


Advantages                                                                                                            

Rapidity: the first testing finishes in only 7 minutes
Accuracy: direct chemiluminescence immunoassay provide accurate result and the linear
correlation coefficient with Europe-America products ≥ 0.99.
Precision: Within batch measurement repeatability: (CV, %) ≤ 5%       
Sample testing: one sample, multiple indicators(ex. Myo, CK-MB, cTnI, etc.) diagnosis
Automation: automatic code scanner, and automated diagnosis.
Stability: The differences between the test results of the 4 hours and 8 hours after the instrument get in
stable state and the test result when the instrument initially gets in stable state is smaller than 10%.
Exclusive techniques----- avoid red blood cells and other impurities interruption.
Superior R&D: hs-cTnI and H-FABP diagnosis is unique in China.
Thorough cardiovascular indicators testing.
Self-developed antigens and self-manufactured antibodies that ensures minimized intra and inter batch difference.


Instrument Parameter                                                                                         

Testing speed: 60 samples/ hour
Sample capacity: 12
Reagent capacity: 6
Refrigeration function for samples and reagents
Testing Mode: Batch, STAT, special samples


Light Emiting Principle                                                                                        

Non-enzymatic chemiluminescence, long reagent stable time

Acridinium ester as the marker, stable performance, without any light source, 

eliminating the influence of other factors.

Sodium hydroxide (NaOH) and hydrogen peroxide(H2O2 ) are excitation substrate.

Structure of NORMAN Automated CLIA System                                            

World's Fastest Seven Minutes Chemiluminescence Immunoassay Analyzer

World's Fastest Seven Minutes Chemiluminescence Immunoassay Analyzer

World's Fastest Seven Minutes Chemiluminescence Immunoassay Analyzer

Sampling System                                                                                                 

Reagent zone
Power supply independent,  magnetic beads levitation systems,refrigeration system is loaded
in reagent area to keep reagent stable,the radio frequency identification technology is adopted
in kit information (calibration curve, time of validity, sample type).

Sample zone
Sample information can be entered manually or scanning recognition
Three testing mode:
Batch, STAT, special sample test
Sample editing mode:
Hospital LIS System
Manual editing
Automatically software generating
Sampling needle
Automatic level detection, stirring mixing system, sampling needle made of titanium alloy material
has good anti-collision function, single needle loads reagents,samples and magnetic beads.Inside
and outside wall cleaning,on outer wall of needle is coated byTeflon,high polish,ensure cross-infection does not exceed 10-5
Incubation zone
36.5±0.5ºC constant temperature incubation.
Incubation abnormity warning, magnetic separation components (independent magnetic separation).
Manipulator
Mechanical grip:grab sample tube, avoid empty or partial catch.
Detection rod:automatic detection of sample tube,evaluate whether sample tube is located accurately.
Card reader
Automatic identification of reagent Kit (type, curve, reagent position), no need manual code scanning.
Magnetic separation components
magnetic separation device closely combines with sample tube,
Nanjing Norman patented technology.


Specification                                                                                                                                                                                                         
World's Fastest Seven Minutes Chemiluminescence Immunoassay Analyzer

Specification of Main Reagents                                                                                                                                                   

World's Fastest Seven Minutes Chemiluminescence Immunoassay Analyzer

Principle of measurement                                                                                   

The Automated Chemiluminescence Analyzer NRM-411-S7 consists of two parts, namely automated reaction system and chemiluminescence assay system. Automated reaction system is the process to bind the luminescent markers indirectly and specifically to the solid phase carrier through incubation and magnetic separation method. Chemiluminescence assay system is the process that when luminescent markers move from the acidic environment suddenly to the alkaline environment, oxidized by the hydrogen peroxide then it emits with maximum wavelength 430nm, which is then captured by the photomultiplier. The system utilizes acridinium ester and its derivatives as luminescent markers, emitting luminescence through injecting trigger solution and finishing within a few seconds, which belongs to flash type chemiluminescence. Acridine ester and its derivatives as luminescent markers for measuring analysis have advantages like simpleness, rapidness, no necessary catalyst, good stability, low non-specific binding and high sensitivity in the reaction, which is a new-type and efficient compound.

Installation Requirements                                                                                                                                            

Installation environment requirements

  • The system is for indoor use only.

  • The bearing platform should be level.

  • The bearing platform should be able to support at least 105kg.

  • The installation site should be well ventilated.

  • The installation site should be free of dust.

  • The installation side should not be in direct sun.

  • The installation site should be kept away from a heat or draft source.

  • The installation site should be free of corrosive gas and flammable gas.

  • The bearing platform should be free of vibration.

  • The installation site should be kept away from large noise and power supply interference.

  • Keep the system away from brush-type motors and electrical contact device that is frequently switched on and off.

  • Do not use such devices as mobile phones and radio transmitter near the system.

  • Power supply requirements

  • Connect the system to a power supply meeting the requirements specified in this manual. For more information, refer to 3.1 Power supply requirements.

  • The system is provided with a three-wire power cord, which has good grounding performance.

  • The system should be connected to a properly-grounded power socket.


Temperature, humidity and atmospheric pressure requirements

  • Working Ambient Temperature: 10°C-30°C.

  • Relative Humidity: ≤70%RH (without condensation).

  • Atmospheric Pressure: 85kPa ~ 106kPa. 



bigPhoto
 Ms. Ying Qin
Department Manager
Tel: 86-25-58602219
Mobile: 138 1471 7578
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Nanjing Norman Biological Technology Co., Ltd [China (Mainland)]


Business Type:Manufacturer
City: Nanjing
Province/State: Jiangsu
Country/Region: China (Mainland)

You May Like: