Nanjing Norman Biological Technology Co., Ltd
|
Payment Terms: | T/T,L/C,WU,Paypal |
Place of Origin: | Jiangsu, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Fully Automated Chemiluminescence immunoassay NRM 411
Self-developed antigens and self-manufactured antibodies that ensures minimized intra
and inter batch difference.
Upgraded version, independent research and development.Accurate testing result,
more than 99% correlation with main stream Europe-America products.
Total Assays
Instrument parameters
Testing speed: 100 samples/ hour
Sample capacity: 36
Reagent capacity: 9
Refrigeration function for samples and reagents
Testing Mode: Batch, STAT, special samples.
Light emitting principle
Non-enzymatic chemiluminescence, long reagent stable time
Acridinium ester as the marker, stable performance, without any light source,
eliminating the influence of other factors.
Sodium hydroxide (NaOH) and hydrogen peroxide(H2O2 ) are excitation substrate.
Structure of NORMAN Automated CLIA System
01. Cuvette loading zone
252cuvettes can be loaded one time and replaced at any time during testing.
Memorize numbers and location of cuvettes.
02. Reagent zone and sample zone
Reagent zone:
Power supply independent, magnetic beads levitation systems, refrigeration system is loaded
in reagent area to keep reagent stable, the radio frequency identification technology is adopted in
kit information (calibration curve, time of validity, sample type).
Sample zone
Sample information can be entered manually or scanning recognition
Three testing mode:
Batch, STAT, special sample test
Sample editing mode:
Hospital LIS System
Manual editing
Automatically software generating
03. Sampling needle
Automatic level detection,stirring mixing system,sampling needle made of titanium alloy material
has good anti-collision function, single needle loads reagents, samples and magnetic beads. Inside
and outside wall cleaning, on outer wall of needle is coated by Teflon, high polish,ensure cross-infection
does not exceed 10-5
04. 04.Incubation zone
36.5±0.5ºC constant temperature incubation, i
Incubation abnormity warning, magnetic separation components (independent magnetic separation).
05. Manipulator (exclusive design)
Mechanical grip: grab sample tube, avoid empty or partial catch.
Detection rod:automatic detection of sample tube,evaluate whether sample tube is located accurately.
06. Card reader
Automatic identification of reagent Kit (type, curve, reagent position), no need manual code scanning.
07. Magnetic separation components
magnetic separation device closely combines with sample tube,
Nanjing Norman patented technology.
Specification
01. Power: | 02. AC220±22V 50±1Hz |
03. Input power: | 04. 500VA |
05. Repeatability: | 06. CV≤5% |
07. Linear: | 08. linear correlation coefficient (r)≥0.99 |
09. Volume: | 10. 1180mm×770mm×785mm |
11. Weight: | 12. 150.0kg |
13. Use: | 14. Indoor |
15. Temperature range: | 16. 10~30ºC |
17. Relative humidity: | 18. ≤70% |
19. Atmospheric pressure: | 20. 85~106kpa |
Specification of main reagents
Principle of measurement
Automated chemiluminescence assay consists of two parts, automatic reaction system and
chemiluminescent assay system. Automated reaction system is the process to indirect
specifically bind the luminescent markers to the solid phase carrier through incubation and
magnetic separation method. Chemiluminescence assay system is the process that when
luminescent markers move from the acidic environment suddenly to the alkaline environment,
oxidized by the hydrogen peroxide then it emits photons with maximum wavelength 430nm,
which is then captured by the photomultiplier.
The system utilizes acridinium ester and its derivatives as luminescent markers, luminescent
through injecting excimer,and complete within a few seconds, belonging to flash type
chemiluminescence. Acridine ester and its derivatives as luminescent markers for measuring
analysis has advantages including simple, fast, no necessary catalyst, good stability, low non-
specific binding and high sensitivity in the reaction,which is a new-type and efficient compound.
Installation Requirements
Installation environment requirements
1.Only for indoor installation and use.The installation environment shall be free of dust,mechanical vibration,
or heavy noise, or power interference, with good ventilation.
2.Place the instrument on a solid and level table, the table carrying capacity shall be no less than
150kg (weight of the instrument)
3.For easy maintenance,leave some space around the instrument,which is easy to connect a variety
of other components, also good for instrument cooling;
4.The instrument shall be far away from strong magnetic fields, strong electric field, water source, corrosive fluids;
do not expose to strong direct light, do not place near heat source. It is prohibitedto use the instrument near strong
radiation source; otherwise it may interfere with normal operation of the instrument.
Power Requirements
1.Power supply: AC220 ± 22V, frequency 50 ± 1Hz;
2.Rated power: 500VA;
3.Fuse sizes: F6A 250V, 5 * 20mm;
4.The instrument requires a properly grounded electrical outlet to provide the required power,do not
use non-own power line;
5.The power outlet location shall allow sufficient space to facilitate plugging and unplugging the power line,
do not put the analyzer in a location difficult to disconnect power.
Temperature, humidity and atmospheric pressure requirements
1. Work Ambient temperature: 10~30ºC, it is recommended to install air-conditioning;
2. Relative humidity ≤70%.
3. Atmospheric pressure: 85~106kpa.
Package and Delivery
About us
Nanjing Norman Biological Technology Co.,Ltd is dedicated to R&D and manufacturing
of Immunofluorescence and automated chemiluminescence system. Founded in 2008,
Norman biological has been upholding the idea that R&D shapes future,concentration
determines success.Now there are over 100 R&D engineers,40% of which hold a PhD
or master's degree.